Description
The OFT/4's have a special low air resistance cowl - the pressure/airflow resistance is <1.3 Pascal at 225m³/h. The pipework above the roofline is twin walled and incorporates an integral condensation drain. This terminal is suitable to extract domestic single fans, high output cooker hood extraction fans and heat recovery ventilation.
Benefits
Large free vent area/Low Pa resistance
The pipework above the roof line is twin walled and incorporates an integral condensation drain
Application
Allows termination through a flat roof to ducting up to 166mm
Diameter: 131mm
Height above roof: 400mm
Flange Diameter: 490mm
Depth below roof: 350mm
Free vent area:12,000mm²
Pa resistance: <1.0
-
Ref oft 4 . Can they be used for void breather vents on a flat roof rather than ducted extracts.
Yes you can use this for either mechanical extraction or passive ventilation, just be aware if using to passively vent the roof space the pipe does protrude 350mm below the flange part of the outlet.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.