Description
Klober Uni-Plain Roof Tile vent is a discreet way of providing 6,000mm² of ventilation coverage to your roof space, due to its clever design it’s almost impossible to view from the roof line. Suitable for both clay and concrete plain tiles with a minimum pitch of 35°, the plain roof tile vent is available in several colours to suit any project.
The built-in downpipe allows direct ventilation to the roof space, while it can also be used as a terminal for soil and ventilation pipes and mechanical extraction systems too when used with an adaptor.
In order to use this vent for extraction you also need to purchase the below adaptor.
Klober Adaptor and Flexipipe for Uni-Plain Tile Vent
Material
Polypropylene/PVC
Minimum pitch
35
Ventilation Area
6000 mm2
Vent tile spacing 5 000 mm2
1.2 m
Vent tile spacing 10 000 mm2
0.6 m
Vent tile spacing 25 000 mm2
0.24 m
Airflow resistance 15 litres/sec
12 pascals
Airflow resistance 30 litres/sec
48 pascals
Airflow resistance 60 litres/sec
191 pascals